++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump
Product Description
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump Features:
1. DC Inverter technology ensure heat pump works well in low ambient temperature even at -20℃.
2. Wide range of temp.: EVI unit work from -20℃.to 43℃, widely used in different environment condition.
3. Higher heating capacity: using enlarging evaporator extracting more heat energy from air will increase COP.
4. Automatic start-up anti-freezing protection when the ambient is below zero degree, the unit is in standby mode more than 30 minutes, automatic anti-freezing device will be started up so that the unit will be protecting in lower ambient temperature.
5. 10% lower working noise with variable speed fan.
6. intelligent system control according different ambient temperature to achieve 20% energy saving and excellent real COP up to 4.42.
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump Parameter:
DC Inverter Heat Pump for cooling/heating & DHW |
Item No. | #PF030DC |
Cooling | Cooling Capacity(kw) | 7.7 |
Capacity Range(kw) | 4.9~8.9 |
Input Power(kw) | 2.6 |
Input Power Range(kw) | 1.5~3.7 |
Rated Current (A) | 12.7 |
Current Range (A) | 7.3~18.1 |
EER | 2.96 |
EER Range | 2.41~3.27 |
Heating | Outlet(kw) | 10.2 |
Outlet Range (kw) | 6.65~13.3 |
Input Power (kw) | 2.4 |
Input Power Range(kw) | 1.4~3.6 |
Rated Current (A) | 11.7 |
Current Range (A) | 6.8~17.6 |
COP | 4.25 |
COP Range | 3.69~4.75 |
DHW | Outlet(kW) | 8.3 |
Outlet Range (kw) | 5.4~10.8 |
Input Power(kw) | 2.5 |
Input Power Range(kw) | 1.4~3.8 |
Rated Current (A) | 12 |
Current Range (A) | 6.8~18.5 |
COP | 3.32 |
COP Range | 2.84~3.86 |
Control System | Japan Importation,Binary design,super-efficient radiator & constant frequency converting |
Compressor | Mitsubishi Dual-rotary D/C Inverter Compressor |
Refrigerant | R410A |
Power Supply | 220V/50Hz |
Working Area | -20~43℃ |
Water Circulation(m³/h) | 1.75 |
Water Pressure Drop(kPa) | 25 |
IP Grade | IPX4 |
Anti-electric shock Rate | I |
Noise in 1M dB(A) | ≤53 |
N.W./G. W.(kg) | 125/135 |
Pipe Size (mm) | DN25 |
Unit Size(W*D*H)mm | 1115*425*710 |
Packing Size(W*D*H)mm | 1180*480*850 |
QTY (20'/40'/40'H) | 48/100/150 |
Cooling work condition: Inlet water temp.12℃,outlet water temp.7℃,dry bulb temp.35℃,wet bulb temp.24℃. |
Heating work condition: Inlet water temp.30℃,outlet water temp.35℃,dry bulb temp.7℃,wet bulb temp.6℃. |
DHW work condition: Inlet water temp.15℃, outlet water temp.55℃, dry bulb temp.7℃, wet bulb temp.6℃. |
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump Photos:
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump:
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump
Installation Reference:
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump welcome to visit Power World heat pump in Shenzhen factory. Let our sample talks! Thanks for your time!
Packaging & Shipping
EER3.27 COP4.75 DC Inverter Air to Water Heat Pump for Heating n Chilling
Company Information
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump
EER3.27 COP4.75 DC Inverter Air to Water Heat Pump for Heating n Chilling Lab:
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump Production Lines:
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump Shows:
++A ERP Air Chiller Heater n Sanitary Hot Water Inverter Air Source Heating Pump for more information, please email me or join WhatsApp: +86-!