• Phone

    86-755-33850802

  • Address

    No. 24, 4th Industrial Zone, Houting, Shajing, Bao'an Dist., Shenzhen, Guangdong, China (Mainland)

  • E-mail

    k@waimaotong.com

LatestProducts

                            -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

                            -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

                            -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

                            -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

                            -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution,OEM,Electronics,Home Appliance,Water Heaters,Heat Pump Water Heaters
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Type:
Air Source Heat Pump
Installation:
Freestanding
Storage / Tankless:
Storage
Housing Material:
galvanized steel optional
Use:
Schools, villas, hospitals, departments, entertainment centers
Certification:
CE, EMC, GS, RoHS, UL, EN14511, EN14825
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
OEM
Model Number:
PF030-KFLWS
Feature:
Conbining Type Big Indoor Unit
Function:
Floor Heating & Sanitary Hot Water
COP:
3.89
Heating Output:
11.5 kw
Power Input:
2.9 kw
Compressor:
Copeland EVI
Refrigerant:
R407C
Water Outlet:
35℃ to 60℃
Work Condition:
-25℃ to 43℃
Power Supply:
220-240V/50Hz
Supply Ability
Supply Ability:
8500 Set/Sets per Year
Packaging & Delivery
Packaging Details
Carton case with plywood outside
Port
SHENZHEN
Lead Time :
Quantity(Sets) 1 - 5 >5
Est. Time(days) 25 To be negotiated

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

 

Product Description

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution Features: 

 

1) Combining design, big indoor unit with key conponents inside, never frozen, wildly be used widely even in -25DegC region, can be high COP reaching 5 above.

2) It meets +A grade above in ERP Energy Label according to EN14825.

3) Wide range of hot water temp. outlet: 35 to 55. With such ability, this device can accomplish low temperature space heating and high temperature space heating both.

4) We adopt intelligent control system to accomplish auto-alteration between sanitary hot water and space heating, firstly achieve 4-season hot water at 55DegC.

5)To prevent the spread of germs to harm human body, even death, control system of this series gives command to heat the water in storage tank to around 70 once a week.

At this temperature in water, more than 85% of germs are defunct. So the electric heater is required to install in water tank.

 

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution Parameter:

EVI Combining Low Temperature Air Source Heat Pump
Item No.#MG-030A-KFLWS
ParametersHeating*Heating capacity (kW) 10.5
Input power (kW) 2.7
Rated current (A) 12.4
COP 3.89
HotWater Outlet(L/H)226
Heating**Heating capacity (kW) 8.4
Input power (kW) 2.6
Rated current (A) 12.3
COP 3.23
HotWater Outlet(L/H)157
Heating***Heating capacity(kW)8.2
Input power(kW)2.25
Rated current (A) 10.3
COP  3.64
Rated outlet water temp.(℃)55
Max outlet hot water(℃)60
 Work Condition-25~43℃
IP GradeIPX4
Standard ConfigurationAnti-electric shock Rate
Noise in 1M (dB(A))≤55
N.W./G.W.(kg)140/155
Diameter of pipe (mm)DN25
Housing MaterialGalvanized steel/Spray/Gray
SizeOutdoor unit (W*D*H)830*310*710
Iutdoor unit (W*D*H)660*385*900
CompressorCopeland  
RefrigerantR407C 
Power supply220V/50Hz
CondenserEfficient tank heat exchanger 
EVI heating exchangerPlate type MTB020-17
EvaporatorU-2/1200*550/φ9.52
Four-way valveDSF-11
Expansion valveDanfoss /Emerson
AC contactor(220V-25A)
Motor (with capacitance)50W*2(4μf*2)
Fanφ420*2
ControllerSingle System(Motorola Chip)
Low-voltage switch0.05/0.15MPa 
High-voltage switch3.0/3.6MPa 
Cable size3*2.5mm2
PackagePolywood packing
Heating* work condition: Inlet water temp.15℃,outlet water temp.55℃,dry bulb temp.20℃, wet bulb temp.15℃.
Heating** work condition: Inlet water temp.9℃, outlet water temp.55℃,dry bulb temp.7℃, wet bulb temp.6℃.
Heating*** work condition: Inlet water temp. 30℃, outlet water temp. 35℃, dry bulb temp. 7℃, wet bulb temp.6℃.
Quality warranty: 7-year for compressor, 18-month for whole unit.
Sampletime: 15-20 days.  Leadtime: 30-35 days after order approval.

 

 

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution Photos:

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution COP Diagram:

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

 

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution:

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution Installation:

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

Choose -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution for: 

1. Sophisticated Components

1.01 Copeland Compressor & Titanium: 

High coefficient of performance over 15-year working, free from normal abrasion various protection system, ensure unit to run smoothly: over current&temp. protecting, high&low voltage protecting. Resist liquid hammer strongly and run steadily in bad condition.

1.02 T6 Fan:

Well selected axial T6 fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.

1.03 Danfoss Electric Expansion Valve:

Danfoss 500 steps Electronic Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.

1.04 High Efficient Tube in Shell Condenser (heat exchanger)

Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.

1.05 Original DuPont Refrigerant

Original DuPont refrigerant, better efficient and ECO friendly, ensure heat pump run reliably and smoothly.

1.06 Advanced welding technology

Nitrogen-welding technology purifies the refrigerant pipe system to avoid the inner residue damages to the compressor; with extra superior welding flux, it makes welding junction steadier, reduce oxidation of copper pipe, prevent gas leakage.

1.07 Outfitting both liquid-storage & gas-liquid separator

Our heat pump outfitting both liquid-storage and gas-liquid separator ensures units run smoothly in different kinds of extreme hostile environment. 

1.08 Eaton (USA) AC contactor & Thermal relay

High quality contactor and thermal relay can freely turn on/off more than 100,000 times. 

1.09 Humanized PCB Design

Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.

1.10 Wide Voltage Transformer

220V-240V AC, 50/60Hz wide voltage transformer in case of voltage fluctuation, ensures unit work smoothly. Current transformer protecting over-current ensure unit working current more accurate.

1.11 Aerial Noise Isolated Material

By using high quality aerial noise isolated material, noise and vibration is avoided perfectly.

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

2. -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution Process:

2.01 Heat Preservations

2.01.02 Copper Tube Heat Preservation.

 

  -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution        

 

2.01.03 Double Valves Heat Preservation

2.01.04 Condenser Heat Preservation

 

 -25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

 

2.01.05 Tube System Case Heat Preservation & Soundproof Craft

2.02 Five Brazing Welding Connection Crafts:

Pipeline Nitrogen Pre-brazing; Assembly Nitrogen Pre-brazing; Machine Assembly Line Welding; Evaporator Elbow Auto Welding; Shunt Manual Welding: Poor Welding         vs. Our Careful Welding Connection, Customized Soldering Flux

2.03 Evaporator Shock-absorption & Soundproof Technology

2.04 Raw Material Purchasing & Supplier Audit

2.05 Capillary Tube Frication & Heat Preservation Technology

2.06 Electronic Case Waterproof Proceed

2.07 Heat Pump Inner Tube Configuration Design Proceed

2.08Ni-Cr Welding Wire Connection & Triple Heat-Shrink Tube Heat Treatment, Waterproof & Heat Preservation Processing

3. Inspection & Test

 

3.01 24 Hour All-ambient-temp. Simulation Independent Laboratory

a. High Temp. Drying/Heating Laboratory

b. All-ambient-temp. Simulation Independent Laboratory

Shoot from outside:                 Making experiment:                      Core of our laboratory:

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

 

3.02 Heat Exchanger 2.8MPa He Pressurized Test

  1. Four Safety Inspection (Safety Earth Connection Inspection, Insulation Resistance Testing, Dielectric Withstand Voltage Testing);
  2. Halogen Test according to IEC 61249-2-21:2003 & IPC-4101B Comply with Br not exceed 900 ppm, Cl not exceed 900 ppm, and the total of Br & Cl not exceed 1500 ppm;
  3. Outlook Inspecting;
  4. Electronic Expansion Valve Testing;
  5. Cooling Operation Testing;
  6. Dehumidifying Operation Testing;
  7. Operation Current Testing (57℃-60℃ water output testing & 7℃-9℃ water output testing);
  8. Brazing, Welding Testing.
 
Packaging & Shipping

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution
-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

 

Company Information

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution shows:

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution

 

-25 Ambient Temp. Cold Region Combining Type Air to Water Heating Pump Solution welcome to pay visit Power World factory in Shenzhen! Please send email or join WhatsApp: +86