86-755-33850802
No. 24, 4th Industrial Zone, Houting, Shajing, Bao'an Dist., Shenzhen, Guangdong, China (Mainland)
19kw Big Indoor Unit Detachable EVI Exhaust Air Heat Pump Water Heater
Super Low Temp. Big Indoor Unit Split Design Air to Water Heater System Feature:
1) Split design, never frozen, wildly be used widely even in -25DegC region, can be high COP reaching 5 above.
2) It meets +A grade above in ERP Energy Label according to EN14825.
3) Wide range of hot water temp. outlet: 35℃ to 55℃. With such ability, this device can accomplish low temperature space heating and high temperature space heating both.
4) We adopt intelligent control system to accomplish auto-alteration between sanitary hot water and space heating, firstly achieve 4-season hot water at 55DegC.
5)To prevent the spread of germs to harm human body, even death, control system of this series gives command to heat the water in storage tank to around 70℃ once a week.
At this temperature in water, more than 85% of germs are defunct. So the electric heater is required to install in water tank.
Remark: There are operation guide in the manual on 3), 4) & 5) .
Super Low Temp. Big Indoor Unit Split Design Air to Water Heater System Parameter:
EVI Split Low Temperature Air Source Heat Pump | |||||
Item No. | #MG-030A-KFLWS | #MG-030B-KFLWS | #MG-050-KFLWS | ||
Parameters | Heating* | Heating capacity (kW) | 10.5 | 11.5 | 18.8 |
Input power (kW) | 2.7 | 2.9 | 4.8 | ||
Rated current (A) | 12.4 | 5.9 | 9 | ||
COP | 3.89 | 3.97 | 3.92 | ||
HotWater Outlet(L/H) | 226 | 247 | 404 | ||
Heating** | Heating capacity (kW) | 8.4 | 9.1 | 15.0 | |
Input power (kW) | 2.6 | 2.8 | 4.7 | ||
Rated current (A) | 12.3 | 5.8 | 8.9 | ||
COP | 3.23 | 3.25 | 3.19 | ||
HotWater Outlet(L/H) | 157 | 170 | 280 | ||
Heating*** | Heating capacity(kW) | 8.2 | 9.1 | 14.8 | |
Input power(kW) | 2.25 | 2.43 | 4 | ||
Rated current (A) | 10.3 | 4.9 | 7.5 | ||
COP | 3.64 | 3.74 | 3.70 | ||
Rated outlet water temp.(℃) | 55 | 55 | 55 | ||
Max outlet hot water(℃) | 60 | 60 | 60 | ||
Work Condition | -25~43℃ | ||||
IP Grade | IPX4 | ||||
Standard Configuration | Anti-electric shock Rate | I | |||
Noise in 1M (dB(A)) | ≤55 | ≤55 | ≤58 | ||
N.W./G.W.(kg) | 140/155 | 140/155 | 190/210 | ||
Diameter of pipe (mm) | DN25 | DN25 | DN25 | ||
Housing Material | Galvanized steel/Spray/Gray | ||||
Size | Outdoor unit (W*D*H) | 830*310*710 | 930*390*1270 | ||
Iutdoor unit (W*D*H) | 660*385*900 | ||||
Compressor | Copeland | ||||
Refrigerant | R407C | ||||
Power supply | 220V/50Hz | 380V/50Hz | 380V/50Hz | ||
Condenser | Efficient tank heat exchanger | ||||
EVI heating exchanger | Plate type MTB020-17 | Plate type MTB020-17 | |||
Evaporator | U-2/1200*550/φ9.52 | L-2/990*1200/φ9.52 | |||
Four-way valve | DSF-11 | DSF-20 | |||
Expansion valve | Danfoss /Emerson | ||||
AC contactor | (220V-25A) | (220V-18A) | |||
Motor (with capacitance) | 50W*2(4μf*2) | 90W*2(5μf) | |||
Fan | φ420*2 | φ490*2 | |||
Controller | Single System(Motorola Chip) | ||||
Low-voltage switch | 0.05/0.15MPa | 0.05/0.15MPa | |||
High-voltage switch | 3.0/3.6MPa | 3.0/3.6MPa | |||
Cable size | 3*2.5mm2 | 3*4mm2+2*2.5mm2 | |||
Package | Polywood packing | ||||
Heating* work condition: Inlet water temp.15℃,outlet water temp.55℃,dry bulb temp.20℃, wet bulb temp.15℃. | |||||
Heating** work condition: Inlet water temp.9℃, outlet water temp.55℃,dry bulb temp.7℃, wet bulb temp.6℃. | |||||
Heating*** work condition: Inlet water temp. 30℃, outlet water temp. 35℃, dry bulb temp. 7℃, wet bulb temp.6℃. | |||||
Quality warranty: 7-year for compressor, 18-month for whole unit. | |||||
Sampletime: 15-20 days. Leadtime: 30-35 days after order approval. |
Super Low Temp. Big Indoor Unit Split Design Air to Water Heater Syste Photos:
Weekly Uperization Super Low Temp. Split Unit Air Water Heater Pump
SCOP Diagram:
Weekly Uperization Super Low Temp. Split Unit Air Water Heater Pump
Weekly Uperization Super Low Temp. Split Unit Air Water Heater Pump Installation:
Choose Weekly Uperization Super Low Temp. Split Unit Air Water Heater Pump for:
1. Sophisticated Components
1.01 Copeland Compressor & Titanium:
High coefficient of performance over 15-year working, free from normal abrasion various protection system, ensure unit to run smoothly: over current&temp. protecting, high&low voltage protecting. Resist liquid hammer strongly and run steadily in bad condition.
1.02 T6 Fan:
Well selected axial T6 fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.
1.03 Danfoss Electric Expansion Valve:
Danfoss 500 steps Electronic Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.
1.04 High Efficient Tube in Shell Condenser (heat exchanger)
Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.
1.05 Original DuPont Refrigerant
Original DuPont refrigerant, better efficient and ECO friendly, ensure heat pump run reliably and smoothly.
1.06 Advanced welding technology
Nitrogen-welding technology purifies the refrigerant pipe system to avoid the inner residue damages to the compressor; with extra superior welding flux, it makes welding junction steadier, reduce oxidation of copper pipe, prevent gas leakage.
1.07 Outfitting both liquid-storage & gas-liquid separator
Our heat pump outfitting both liquid-storage and gas-liquid separator ensures units run smoothly in different kinds of extreme hostile environment.
1.08 Eaton (USA) AC contactor & Thermal relay
High quality contactor and thermal relay can freely turn on/off more than 100,000 times.
1.09 Humanized PCB Design
Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.
1.10 Wide Voltage Transformer
220V-240V AC, 50/60Hz wide voltage transformer in case of voltage fluctuation, ensures unit work smoothly. Current transformer protecting over-current ensure unit working current more accurate.
1.11 Aerial Noise Isolated Material
By using high quality aerial noise isolated material, noise and vibration is avoided perfectly.
2. Weekly Sterilization Low Temp. Split Unit Air to Water Heater Pump Process:
2.01 Heat Preservations
2.01.02 Copper Tube Heat Preservation.
2.01.03 Double Valves Heat Preservation
2.01.04 Condenser Heat Preservation
2.01.05 Tube System Case Heat Preservation & Soundproof Craft
2.02 Five Brazing Welding Connection Crafts:
Pipeline Nitrogen Pre-brazing; Assembly Nitrogen Pre-brazing; Machine Assembly Line Welding; Evaporator Elbow Auto Welding; Shunt Manual Welding: Poor Welding vs. Our Careful Welding Connection, Customized Soldering Flux
2.03 Evaporator Shock-absorption & Soundproof Technology
2.04 Raw Material Purchasing & Supplier Audit
2.05 Capillary Tube Frication & Heat Preservation Technology
2.06 Electronic Case Waterproof Proceed
2.07 Heat Pump Inner Tube Configuration Design Proceed
2.08Ni-Cr Welding Wire Connection & Triple Heat-Shrink Tube Heat Treatment, Waterproof & Heat Preservation Processing
3. Inspection & Test
3.01 24 Hour All-ambient-temp. Simulation Independent Laboratory
a. High Temp. Drying/Heating Laboratory
b. All-ambient-temp. Simulation Independent Laboratory
Shoot from outside: Making experiment: Core of our laboratory:
3.02 Heat Exchanger 2.8MPa He Pressurized Test
Weekly Uperization Super Low Temp. Split Unit Air Water Heater Pump
Weekly Uperization Super Low Temp. Split Unit Air Water Heater Pump
Weekly Uperization Super Low Temp. Split Unit Air Water Heater Pump shows:
Super Low Temp. Big Indoor Unit Split Design Air to Water Heater System welcome to pay visit Power World factory in Shenzhen! Thanks a lot for your time! Please send me.