• Phone

    86-755-33850802

  • Address

    No. 24, 4th Industrial Zone, Houting, Shajing, Bao'an Dist., Shenzhen, Guangdong, China (Mainland)

  • E-mail

    k@waimaotong.com

LatestProducts

                            220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

                            220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

                            220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

                            220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water,OEM/Power World,Electronics,Home Appliance,Water Heaters,Heat Pump Water Heaters
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Type:
Air Source Heat Pump
Installation:
Freestanding
Storage / Tankless:
Storage
Housing Material:
galvanized steel
Use:
Schools, villas, hospitals, departments, entertainment centers
Certification:
CE, EMC, GS, RoHS, UL, EN14511, EN14852
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
OEM/Power World
Model Number:
#PF030-KFLWS
Work condition:
-25℃ to 43℃
Feature:
Split Design
Function:
House Heating or Hot Water
COP:
3.9
Heating Outlet:
10.5kw
Power Input:
2.25kw
Compressor:
Copeland EVI
Refrigerant:
R407C/OEM
Water Temp. Outlet:
35℃ to 60℃
Power Supply:
220-240V/50Hz
Supply Ability
Supply Ability:
45000 Set/Sets per Year
Packaging & Delivery
Packaging Details
Carton case with plywood outside
Port
SHENZHEN
Lead Time :
20 days

    10.5kw Combining Heat Pump Water Heating All Day Hot Water n Room Heated

Product Description

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water Feature: 

1.Split design, never frozen and lower noise indoor, be used widely even in very cold area like -25DegC.

2.Very high COP reach 5 or above.
3.Use plate heat exchanger to get higher heating capacity.
4.Environmental friendly and safe.

5.Automatic intelligent control system  

 

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water Parameters:

 

EVI Split Low Temperature Air Source Heat Pump
Item No.PF030-KFLWS 
Parametersheating*Heating capacity (kW) 10.5
Input power (kW) 2.7
Rated current (A) 12.4
COP 3.89
Production capacity (L/H)226
heating**Heating capacity (kW) 8.4
Input power (kW) 2.6
Rated current (A) 12.3
COP 3.23
Production capacity (L/H)157
Rated outlet hot water temperature ()55
Highest outlet hot water temperature()60
 Working  area -25~43
IP Grade (Level of protection)IPX4
Anti-electric shock Rate
Noise (dB(A))55
Net weight/Gross weight(kg)140/155
Diameter of pipe (mm)DN25
Standard ConfigurationMetel plateGalvanized steel/Spray/Gray
Body sizeOutdoor unit (W*D*H)830*490*1160
Iutdoor unit (W*D*H)500*330*810
CompressorCopeland  
RefrigerantR407C 
Power supply380V/50Hz
CondenserEfficient tank heat exchanger 
Economy unit(EVI heating exchanger)Plate type MTB020-17
EvaporatorU-2/1200*550/φ9.52
Four-way valveDSF-11
Expansion valveDanfoss /Emerson
AC contactor(220V-25A)
Motor (with capacitance)50W*2(4μf*2)
Fanφ420*2
ControllerSingle System(Motorola Chip)
Low-voltage switch0.05/0.15MPa 
High-voltage switch3.0/3.6MPa 
Power line connect with unit3*2.5mm2
PackagePolywood packing
Heating* work condition: Inlet water temp. 15, outlet water temp. 55, dry bulb temp. 20, wet bulb temp. 15.
Heating** work condition: Inlet water temp. 9, outlet water temp. 55, dry bulb temp. 7, wet bulb temp. 6.

 

 

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water Photos:

 

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

 

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

 

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water - HEATING COP Curve:

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

 

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water -- Domestic Hot Water COP Curve:

 

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

 

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water Advantages: 

1. Sophisticated Components

 

1.01 Copeland Compressor & Titanium:

High coefficient of performance over 15-year working, free from normal abrasion various protection system, ensure unit to run smoothly: over current&temp. protecting, high&low voltage protecting. Resist liquid hammer strongly and run steadily in bad condition.

1.02 T6 Fan:

Well selected axial T6 fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.

1.03 Danfoss Electric Expansion Valve:

Danfoss 500 steps Electronic Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.

1.04 High Efficient Tube in Shell Condenser (heat exchanger)

Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.

1.05 Original DuPont Refrigerant

Original DuPont refrigerant, better efficient and ECO friendly, ensure heat pump run reliably and smoothly.

1.06 Advanced welding technology

Nitrogen-welding technology purifies the refrigerant pipe system to avoid the inner residue damages to the compressor; with extra superior welding flux, it makes welding junction steadier, reduce oxidation of copper pipe, prevent gas leakage.

1.07 Outfitting both liquid-storage & gas-liquid separator

Our heat pump outfitting both liquid-storage and gas-liquid separator ensures units run smoothly in different kinds of extreme hostile environment. 

 

1.08 Eaton (USA) AC contactor & Thermal relay

High quality contactor and thermal relay can freely turn on/off more than 100,000 times. 

 

1.09 Humanized PCB Design

Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.

1.10 Wide Voltage Transformer

 

220V-240V AC, 50/60Hz wide voltage transformer in case of voltage fluctuation, ensures unit work smoothly. Current transformer protecting over-current ensure unit working current more accurate.

 

1.11 Aerial Noise Isolated Material

By using high quality aerial noise isolated material, noise and vibration is avoided perfectly.

  

2. 220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water Manufacturing Process:

 

2.01 Heat Preservations

2.01.02 Copper Tube Heat Preservation.

 

  220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water        

 

2.01.03 Double Valves Heat Preservation

2.01.04 Condenser Heat Preservation

 

 220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

 

2.01.05 Tube System Case Heat Preservation & Soundproof Craft

 

2.02 Five Brazing Welding Connection Crafts:

Pipeline Nitrogen Pre-brazing, Assembly Nitrogen Pre-brazingMachine Assembly Line Welding, Evaporator Elbow Auto Welding, Shunt Manual Welding: Poor Welding vs. our Careful Welding Connection, Customized Soldering Flux

 

2.03 Evaporator Shock-absorption & Soundproof Technology

2.04 Raw Material Purchasing & Supplier Audit

2.05 Capillary Tube Frication & Heat Preservation Technology

2.06 Electronic Case Waterproof Proceed

2.07 Heat Pump Inner Tube Configuration Design Proceed

2.08 Ni-Cr Welding Wire Connection & Triple Heat-Shrink Tube Heat Treatment, Waterproof & Heat Preservation Processing

 

3. Inspection & Test

 

3.01 24 Hour All-ambient-temp. Simulation Independent Laboratory

a. High Temp. Drying/Heating Laboratory

b. All-ambient-temp. Simulation Independent Laboratory

Shoot from outside:                        Testing:                      Core of our laboratory:

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

3.02 Heat Exchanger 2.8MPa He Pressurized Test

  1. Four Safety Inspection (Safety Earth Connection Inspection, Insulation Resistance Testing, Dielectric Withstand Voltage Testing);
  2. Halogen Test according to IEC 61249-2-21:2003 & IPC-4101B Comply with Br not exceed 900 ppm, Cl not exceed 900 ppm, and the total of Br & Cl not exceed 1500 ppm;
  3. Outlook Inspecting;
  4. Electronic Expansion Valve Testing;
  5. Cooling Operation Testing;
  6. Dehumidifying Operation Testing;
  7. Operation Current Testing (57℃-60℃ water output testing & 7℃-9℃ water output testing);
  8. Brazing, Welding Testing;
220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water Installation for House Heating and Domestic Hot Water:
220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water
 
Packaging & Shipping

 220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water

 

Company Information

220v Split 10.5kw Air Water Heating Pump Room Ground Heater Sanitary Hot Water welcome to visit Power World factory in Shenzhen and Dongguan!

Please send email or join WhatsApp: +86-for more information in detail!